Escritório de Montreal

Operações no Canadá

Sede em Pequim

Fabricação na China

EN · ES · FR · CN

Enviar e-mail

sales@vikkins.com

WhatsApp

+86-13910054364

Rockwool Wall Sandwich Panel

Class A non-combustible mineral wool core sandwiched between Galvalume steel sheets. The fire-safe choice for industrial, logistics and high-occupancy commercial roofs — with strong sound absorption and proven thermal stability.

N.º do modelo.

VK-RWR1/2/3

Material do núcleo

Basalt Mineral Wool

Espessura total

50 / 75 / 100 / 120 / 150 / 200 mm

Largura efetiva

960 / 1000 mm

Classificação de resistência ao fogo

Class A · Non-combustible · up to 1000 °C

Sound Absorption

Rw up to 35 dB

When fire safety cannot be compromised

A

Non-combustible Class A core

Spun from molten basalt rock at 1500 °C, the mineral wool core is fundamentally inorganic and will not burn, melt or release toxic smoke at temperatures up to 1000 °C. Tested to GB 8624 Class A1 / EN 13501 A2-s1,d0.

Mandatory for buildings over 24 m, public-occupancy structures, oil & gas facilities, lithium battery factories and data centres in most jurisdictions.

dB

Acoustic & thermal stability

Unlike foam cores, mineral wool retains its insulation value through repeated thermal cycles and decades of service — no shrinkage, no off-gassing, no R-value decay.

Fibrous structure absorbs airborne sound, delivering Rw values up to 35 dB — ideal for noisy production halls, music venues and any roof exposed to rain impact.

Rockwool Wall Panel parameters

ParâmetroValor
Aspecto da superfíciePrensagem de fitas · Totalmente plana
Espessura do aço0.4–0.8 mm (outer + inner sheet)
Densidade do núcleo100 / 120 / 140 kg/m³
Espessura total50 / 75 / 100 / 120 / 150 / 200 mm
Largura efetiva960 / 1000 mm

Maximum allowable deflection · surface load capacity

Espessura
mm
Heat Insulation
Coefficient
K/m²·h·°C
Surface Load Capacity (P=kg/m²)
L Span configuration
6080100120150
500.86L=29302740255023302060
800.54L=39003490319029302510
1000.43L=43503860356032302780
Nota: Os valores da capacidade de carga superficial representam os limites máximos de deflexão admissíveis. P = carga uniforme (kg/m²); L = vão (mm). Cálculos baseados numa densidade do núcleo de Rockwool de 100–140 kg/m³.

Buildings where Class A fire performance is mandated

01

Lithium Battery & EV Factories

Mandatory non-combustible envelope to contain thermal runaway events. Compliant with GB 51377 fire codes.

02

Data Centres & Telecom

Zero combustible material above critical IT infrastructure. Absorbs HVAC and equipment noise.

03

Petrochemical Facilities

Refineries, LNG depots and chemical plants where any organic material in the envelope is prohibited.

04

High-occupancy Public Buildings

Stadiums, exhibition halls, hospitals, schools — any building over 24 m or with high public occupancy.

N.º do modelo.

VK-GWR

Material do núcleo

Glass Wool Fibre

Espessura total

50 / 75 / 100 / 120 / 150 mm

Largura efetiva

960 / 1000 mm

Classificação de resistência ao fogo

Class A2 · up to 700 °C

Edge Treatment

PU Side Seal

Light-weight glass wool with PU side seal

A

Glass Wool Core · Light & Insulating

Spun from molten glass at > 1300 °C, glass wool fibre offers excellent thermal insulation at lower density than rockwool. Class A2 fire rating with low thermal conductivity ~0.035 W/m·K.

Particularly suited to office buildings, conference halls, exhibition centres and other roofs where panel weight reduction is desirable while keeping fire safety strong.

dB

PU Side Seal & Edge Protection

GWR panels feature an integrated polyurethane side seal that closes the cut-edge of the glass wool core, preventing fibre release, water ingress and edge crushing during install — a key advantage over plain mineral wool panels.

Two stock profiles available — single-step trapezoid and double-step low profile — selected by aesthetics or required deflection.

Glass Wool Wall Panel parameters

ParâmetroValor
Aspecto da superfíciePrensagem de fitas · Totalmente plana
Espessura do aço0.4–0.8 mm (outer + inner sheet)
Densidade do núcleo48 / 64 / 80 kg/m³
Espessura total50 / 75 / 100 / 120 / 150 / 200 mm
Largura efetiva960 / 1000 mm

Maximum allowable deflection · surface load capacity

Espessura
mm
Heat Insulation
Coefficient
K/m²·h·°C
Surface Load Capacity (P=kg/m²)
L Span configuration
80100120150200
500.68L=29503530322028802500
750.54L=46004110372033602910
1000.43L=49804450408036303150

Nota: Os valores da capacidade de carga superficial representam os limites máximos de deflexão admissíveis. P = carga uniforme (kg/m²); L = vão (mm). Cálculos baseados numa densidade do núcleo de Rockwool de 100–140 kg/m³.

Roofs where weight savings matter as much as thermal performance

01

Office & Commercial Buildings

Common choice for office complexes, exhibition halls and conference centres where light weight + good acoustic dampening matter.

02

Sports & Cultural Venues

Stadiums, gymnasiums, theatre and concert venues benefit from glass wool's superior sound absorption.

03

Cold-storage & Logistics Hubs

PU side-seal closes thermal bridges at panel joints — ideal where vapour control and energy efficiency matter.

04

Educational & Public Institutions

Schools, hospitals and government buildings where moderate fire-rating + lightweight roofs simplify retrofits.

Specify a Rockwool Wall Sandwich Panel for Your Project

Send us your span, fire-rating target and acoustic requirements — our engineering desk will return a fully detailed panel package, typically within two working days.