{"id":1546,"date":"2024-12-10T21:14:00","date_gmt":"2024-12-10T21:14:00","guid":{"rendered":"https:\/\/vikkins.com\/?p=1546"},"modified":"2026-06-10T21:18:19","modified_gmt":"2026-06-10T21:18:19","slug":"steel-structure-system-guide-vikkins","status":"publish","type":"post","link":"https:\/\/vikkins.com\/ru\/steel-structure-system-guide-vikkins\/","title":{"rendered":"VIKKINS Steel Structure System: High-Strength, Lightweight Performance Across 9\u2013180m Spans and 90+ Countries"},"content":{"rendered":"<p>The steel structure system is the structural backbone of modern industrial and commercial construction. VIKKINS delivers a complete, engineered package \u2014 from primary portal frame to secondary purlins, wall girts, bracing, and all accessories \u2014 combining\u00a0<strong>high strength, lightweight performance, efficient installation, and significantly reduced construction periods<\/strong>. Applied across warehouses, workshops, cold storage, offices, hotels, labour camps, schools, and more.<\/p>\n<h2>System Performance at a Glance<\/h2>\n<table style=\"height: 110px;\" width=\"689\" cellspacing=\"8\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<div>9\u2013180m<\/div>\n<div>Span Range<\/div>\n<\/td>\n<td>\n<div>6<\/div>\n<div>Frame Systems<\/div>\n<\/td>\n<td>\n<div>32T<\/div>\n<div>Max Crane<\/div>\n<\/td>\n<td>\n<div>SA2.5<\/div>\n<div>Shot Blast<\/div>\n<\/td>\n<td>\n<div>90+<\/div>\n<div>Countries<\/div>\n<\/td>\n<td>\n<div>14<\/div>\n<div>Mfg Steps<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>What Is a Steel Structure System?<\/h2>\n<p>A\u00a0<strong>steel structure system<\/strong>\u00a0is a complete, engineered framework of primary and secondary structural members forming the load-bearing skeleton of a building. Fabricated off-site to precise tolerances and delivered as a bolt-together package \u2014 no curing time, no formwork, no wet trades required.<\/p>\n<p><strong>Q235 and Q345 structural steel grades<\/strong>\u00a0deliver tensile strength of 235\u2013345 MPa, yet weigh a fraction of equivalent concrete. This means lighter foundations, faster erection, longer achievable spans, and a building that can be expanded or modified throughout its life.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-1551 size-large\" src=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM-1024x628.webp\" alt=\"\u0421\u0438\u0441\u0442\u0435\u043c\u0430 \u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439\" width=\"800\" height=\"491\" srcset=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM-1024x628.webp 1024w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM-300x184.webp 300w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM-768x471.webp 768w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM-18x12.webp 18w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_31_21-PM.webp 1200w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Roof System: Components and Functions<\/h2>\n<p>The roof system is the primary weather barrier and thermal envelope. Every component serves a specific structural or performance function.<\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Roof Cladding<\/div>\n<div>Corrugated steel sheets providing weather resistance and long-term durability against rain, wind, and UV.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Ridge Cap<\/div>\n<div>Covers the roof apex to prevent water ingress and enhance long-term weathertight durability.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Z Purlin<\/div>\n<div>Horizontal members spanning between rafter beams, supporting roof cladding and transferring loads to the primary frame.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Rafter Beam<\/div>\n<div>Primary structural members following the roof slope, supporting the purlin system and transferring loads to frame columns.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Eave Strut<\/div>\n<div>Supports the eave purlin and provides structural connection for the roof edge, tying roof and wall systems together.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Roof Ventilator<\/div>\n<div>Enhances natural airflow and reduces heat and moisture buildup \u2014 critical for workshops and production facilities.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Skylight<\/div>\n<div>Allows natural daylight into the building interior, reducing artificial lighting requirements and improving working conditions.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Gutter &amp; Down Spout<\/div>\n<div>Collects rainwater from the roof and directs it to ground drainage, protecting the foundation and site from water accumulation.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Wall Frame System: Components and Functions<\/h2>\n<p>The wall frame system transfers lateral wind and seismic loads while providing structural support for wall cladding.<\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Rigid Frame (Portal Frame)<\/div>\n<div>Main structural frame of columns and rafters, designed to resist both vertical gravity loads and lateral wind and seismic loads.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Main Frame Column<\/div>\n<div>Vertical steel columns collecting all structural loads from the roof and transferring them to the building&#8217;s foundation.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>End Wall Column<\/div>\n<div>Columns at building end walls, supporting the gable frame and end wall cladding against wind pressure.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Side Wall Girt<\/div>\n<div>Horizontal members attached to side wall columns, supporting wall cladding panels and transferring wind loads into the primary frame.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>End Wall Girt<\/div>\n<div>Horizontal members on end walls supporting end wall cladding and enhancing overall structural stability of the gable ends.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Bracing Rod<\/div>\n<div>Diagonal tension rods providing lateral stability, preventing racking of the building under wind or seismic loads.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Wall Cladding<\/div>\n<div>Protects the building from weather while improving thermal and acoustic performance \u2014 single-skin or insulated sandwich panel.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td>\n<table cellspacing=\"0\" cellpadding=\"14\">\n<tbody>\n<tr>\n<td>\n<div>Canopy<\/div>\n<div>Provides shade and weather protection over doors and wall openings, protecting the building entrance from direct rain.<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_1552\" aria-describedby=\"caption-attachment-1552\" style=\"width: 800px\" class=\"wp-caption alignnone\"><img decoding=\"async\" class=\"wp-image-1552 size-large\" src=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM-1024x512.webp\" alt=\"\u0421\u0438\u0441\u0442\u0435\u043c\u0430 \u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439\" width=\"800\" height=\"400\" srcset=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM-1024x512.webp 1024w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM-300x150.webp 300w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM-768x384.webp 768w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM-18x9.webp 18w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/ChatGPT-Image-Jun-10-2026-01_57_35-PM.webp 1200w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption id=\"caption-attachment-1552\" class=\"wp-caption-text\">\u00a0\u0421\u0438\u0441\u0442\u0435\u043c\u0430 \u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439<\/figcaption><\/figure>\n<h2>Primary Structure: H-Beam Specification<\/h2>\n<p>All primary load-bearing members are fabricated from<a href=\"https:\/\/www.worldsteel.org\" target=\"_blank\" rel=\"noopener\">\u00a0<strong>Q235B or Q345B grade welded H-section steel<\/strong><\/a>. Three series cover the full range of structural requirements.<\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Series<\/th>\n<th>Size Range (H\u00d7B)<\/th>\n<th>Web Thickness<\/th>\n<th>Unit Weight<\/th>\n<th>Application<\/th>\n<\/tr>\n<tr>\n<td><strong>HW Wide Flange<\/strong><\/td>\n<td>100\u00d7100 \u2013 400\u00d7400mm<\/td>\n<td>6\u201313mm<\/td>\n<td>16.9\u2013171.7 kg\/m<\/td>\n<td>Columns, heavily loaded frames<\/td>\n<\/tr>\n<tr>\n<td><strong>HM Medium Flange<\/strong><\/td>\n<td>150\u00d7100 \u2013 600\u00d7300mm<\/td>\n<td>6\u201312mm<\/td>\n<td>20.7\u2013147.0 kg\/m<\/td>\n<td>Main frame rafters, crane girders<\/td>\n<\/tr>\n<tr>\n<td><strong>HN Narrow Flange<\/strong><\/td>\n<td>100\u00d750 \u2013 600\u00d7200mm<\/td>\n<td>5\u201311mm<\/td>\n<td>9.3\u2013102.2 kg\/m<\/td>\n<td>Long-span roof beams, secondary members<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Secondary Structure: C Purlin and Z Purlin<\/h2>\n<p>C and Z purlins span between primary rafters to support roof and wall cladding. Z purlins interlock for continuous spans with higher load capacity \u2014 preferred for longer bay spacings. Material: Q235 steel.<\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Type<\/th>\n<th>Height Range<\/th>\n<th>Thickness<\/th>\n<th>Unit Weight<\/th>\n<th>Inertia Jx<\/th>\n<\/tr>\n<tr>\n<td><strong>C Purlin<\/strong><\/td>\n<td>80\u2013450mm<\/td>\n<td>2.5\u20133.0mm<\/td>\n<td>3.93\u201316.25 kg\/m<\/td>\n<td>46.22\u20135,650 cm\u2074<\/td>\n<\/tr>\n<tr>\n<td><strong>Z Purlin<\/strong><\/td>\n<td>140\u2013200mm<\/td>\n<td>2.5\u20133.0mm<\/td>\n<td>5.89\u20138.48 kg\/m<\/td>\n<td>217.26\u2013578.47 cm\u2074<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>14-Step Manufacturing Process<\/h2>\n<p>Every VIKKINS H-beam structural member passes through a\u00a0<strong>14-step manufacturing process<\/strong>\u00a0\u2014 from raw plate inspection through CNC cutting, assembly, welding,\u00a0<strong>SA2.5 shot blasting<\/strong>, painting, to final packaged delivery.<\/p>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>Complete Manufacturing Flow<\/td>\n<td>14 STEPS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<div>1<\/div>\n<div>Plate<\/div>\n<div>Raw plate inspection<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>2<\/div>\n<div>Cutting<\/div>\n<div>CNC cutting to size<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>3<\/div>\n<div>Suspending<\/div>\n<div>Move to assembly<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>4<\/div>\n<div>T Tape Assembling<\/div>\n<div>T-shaped assembly<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>5<\/div>\n<div>90\u00b0 Verturning<\/div>\n<div>Rotate 90\u00b0<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>6<\/div>\n<div>Hoisting<\/div>\n<div>Hoist to next station<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>7<\/div>\n<div>H-section Assemble<\/div>\n<div>Beam to column<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td>\n<div>8<\/div>\n<div>Sew Welding<\/div>\n<div>Fix in place<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>9<\/div>\n<div>90\u00b0 Verturning<\/div>\n<div>Rotate another 90\u00b0<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>10<\/div>\n<div>Flange Plate Rectifying<\/div>\n<div>Ensure flatness<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>11<\/div>\n<div>Bar Board Matches Welding<\/div>\n<div>Weld stiffeners<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>12<\/div>\n<div>Shot Blasting<\/div>\n<div>Remove rust SA2.5<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>13<\/div>\n<div>Paint<\/div>\n<div>Primer + top coat<\/div>\n<\/td>\n<td>\n<div><\/div>\n<\/td>\n<td>\n<div>14<\/div>\n<div>Packaged &amp; Leaving Plant<\/div>\n<div>Pack, load &amp; deliver<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"alignnone wp-image-1553 size-large\" src=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW-1024x512.webp\" alt=\"\u0421\u0438\u0441\u0442\u0435\u043c\u0430 \u0441\u0442\u0430\u043b\u044c\u043d\u044b\u0445 \u043a\u043e\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u0439\" width=\"800\" height=\"400\" srcset=\"https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW-1024x512.webp 1024w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW-300x150.webp 300w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW-768x384.webp 768w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW-18x9.webp 18w, https:\/\/vikkins.com\/wp-content\/uploads\/2026\/06\/COMPLETE-MANUFACTURING-FLOW.webp 1200w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h2>Frame Systems \u2014 Select by Application<\/h2>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Frame Type<\/th>\n<th>Span<\/th>\n<th>Height<\/th>\n<th>Key Feature<\/th>\n<th>Best For<\/th>\n<\/tr>\n<tr>\n<td><strong>Portal Frame<\/strong><\/td>\n<td>9\u201318m<\/td>\n<td>3\u20137m<\/td>\n<td>Uniform cross-section, local haunching<\/td>\n<td>Small workshops, storage<\/td>\n<\/tr>\n<tr>\n<td><strong>Crane Frame<\/strong><\/td>\n<td>12\u201324m<\/td>\n<td>3\u20138m<\/td>\n<td>Crane capacity up to 32T<\/td>\n<td>Heavy manufacturing, machinery<\/td>\n<\/tr>\n<tr>\n<td><strong>Variable Frame<\/strong><\/td>\n<td>18\u201336m<\/td>\n<td>3\u20139m<\/td>\n<td>Variable cross-section, high-strength bolt<\/td>\n<td>Large warehouses, logistics<\/td>\n<\/tr>\n<tr>\n<td><strong>Sandwich Frame<\/strong><\/td>\n<td>12\u201324m<\/td>\n<td>6\u201310m<\/td>\n<td>Integrated insulated panel system<\/td>\n<td>Cold storage, offices, hotels<\/td>\n<\/tr>\n<tr>\n<td><strong>Mixed Section<\/strong><\/td>\n<td>9\u201318m<\/td>\n<td>3\u20138m<\/td>\n<td>Uniform column, variable beam<\/td>\n<td>Labour camps, compact units<\/td>\n<\/tr>\n<tr>\n<td><strong>Super Long Span<\/strong><\/td>\n<td>72\u2013180m<\/td>\n<td>3\u20138m<\/td>\n<td>Mid-span wobble columns to 180m<\/td>\n<td>Hangars, arenas, logistics hubs<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Application Matrix<\/h2>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<th>Application<\/th>\n<th>Recommended Frame<\/th>\n<th>Typical Span<\/th>\n<th>Key Requirement<\/th>\n<\/tr>\n<tr>\n<td><strong>Warehouse<\/strong><\/td>\n<td>Variable \/ Super Long Span<\/td>\n<td>24\u2013180m<\/td>\n<td>Maximum clear floor area<\/td>\n<\/tr>\n<tr>\n<td><strong>Workshop<\/strong><\/td>\n<td>Crane \/ Variable Frame<\/td>\n<td>18\u201336m<\/td>\n<td>Crane capacity, heavy loading<\/td>\n<\/tr>\n<tr>\n<td><strong>Cold Storage<\/strong><\/td>\n<td>Sandwich Frame<\/td>\n<td>12\u201324m<\/td>\n<td>Thermal envelope, vapour control<\/td>\n<\/tr>\n<tr>\n<td><strong>Office Building<\/strong><\/td>\n<td>Sandwich \/ Mixed Section<\/td>\n<td>12\u201324m<\/td>\n<td>Multi-storey, architectural finish<\/td>\n<\/tr>\n<tr>\n<td><strong>Hotel<\/strong><\/td>\n<td>Sandwich Frame<\/td>\n<td>12\u201324m<\/td>\n<td>Speed, room layout flexibility<\/td>\n<\/tr>\n<tr>\n<td><strong>Labour Camp<\/strong><\/td>\n<td>Portal \/ Mixed Section<\/td>\n<td>9\u201318m<\/td>\n<td>Rapid deployment, cost efficiency<\/td>\n<\/tr>\n<tr>\n<td><strong>School \/ Public Building<\/strong><\/td>\n<td>Variable \/ Sandwich Frame<\/td>\n<td>18\u201336m<\/td>\n<td>Large open spans, low maintenance<\/td>\n<\/tr>\n<tr>\n<td><strong>Hangar \/ Arena<\/strong><\/td>\n<td>Super Long Span<\/td>\n<td>72\u2013180m<\/td>\n<td>Maximum span, structural efficiency<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table cellspacing=\"0\" cellpadding=\"24\">\n<tbody>\n<tr>\n<td>&#8220;From a 9m workshop to a 180m clear-span logistics centre \u2014 the VIKKINS steel structure system scales to any project, in any climate, on any continent.&#8221;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Why VIKKINS Steel Structure System<\/h2>\n<p>With production bases in Cangzhou and Harbin, Canadian operational management, and delivery to more than\u00a0<strong>90 countries<\/strong>, VIKKINS combines manufacturing scale and cost efficiency with the quality management standards that global clients demand \u2014 holding\u00a0<strong>ISO 9001, ISO 14001, and ISO 45001<\/strong>\u00a0certification.<\/p>\n<p>Every project is supported by complete structural drawings, erection manuals, and material schedules. For full specifications, visit\u00a0<a href=\"https:\/\/vikkins.com\/ru\/products\/steel-structure-system\/\" target=\"_blank\" rel=\"noopener\">vikkins.com\/products\/steel-structure-system<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>The steel structure system is the structural backbone of modern industrial and commercial construction. VIKKINS delivers a complete, engineered package \u2014 from primary portal frame to secondary purlins, wall girts, bracing, and all accessories \u2014 combining\u00a0high strength, lightweight performance, efficient installation, and significantly reduced construction periods. Applied across warehouses, workshops, cold storage, offices, hotels, labour [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1551,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1,17],"tags":[],"class_list":["post-1546","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-company-news-2","category-product-knowledge"],"acf":[],"_links":{"self":[{"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/posts\/1546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/comments?post=1546"}],"version-history":[{"count":1,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/posts\/1546\/revisions"}],"predecessor-version":[{"id":1558,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/posts\/1546\/revisions\/1558"}],"wp:attachment":[{"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/media?parent=1546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/categories?post=1546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vikkins.com\/ru\/wp-json\/wp\/v2\/tags?post=1546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}